Hosppro Healthcare Co.Ltd
|
|
| |
|
|
|
|

|

|
Click to enlarge image
|
Model Number |
HLM-1-30A |
1 working principles of laser
Holmium Laser is produced by pulse equipment of solid laser. Pulse equipment of solid laser is made by a kind of crystalloid (Cr: Tm: Ho: YAG) which based on Yttrium Aluminum Garnet (YAG), mixing with Cr, Tm and Ho. The deferent wavelength is 2.1 micron which is able to be absorbed by body tissue. With the conduction of optical fibers, the wave could reach every part of pathological tissue to cauterize, freeze, vaporize and incise it.
2 the structure of the machine & working mechanism
Therapeutic apparatus is constituted by Laser, laser electrical source, control system, light-transmited system, cooling system and safeguard system. (Working mechanism, See digram 1)
Capability and Characteristic
1 When Holmium Laser with 2.1 micron wavelength irradiates body tissues, it will be absorbed quickly by the water (about 70-90%) in it. It can produce an identical & steady penetrating depth (0.4mm), and not be influenced by pigment. All of the above insure precision of operations in the fields where important organs, nerves and blood vessels are assembled, so it is safe to incise, vaporize, stanch, spall rocks and smash in precision. Therefore, whatever in precision or safty of operations are above comparion of other kinds of laser therapeutic apparatus.
2 The recycled optical fiber transmission system not only can penetrate the exterior and interior tissue, but also can do endovascular stent grafts conveniently by various tools and ready endoscopes, which will avoid operations, reduce operation charges and alleviate pains of patients.
3 The holmium laser(2.1 micron) stays at the infrared region where people could not see. So paramedics can use it without wearing coloured glasses, because the eyeshot is clear.
4 The equipment set and choose parameters with microcomputers which can show working states digitally, follow and display power automatically, and also can do safety self-checked, self-locked and instant-terminal fittings. It is convenient on operation and the capability is safe.
Assortment and type signment
1 assortment
According to GB9706.1�1995:
(1) By types of electric shock: (it belongs to) Sort I;
(2) By degrees of protecting from electric shock: BF type equipment;
(3) By degrees of protecting from deleterious steep: common facility (akind airtight equipment that cannot defend the steep);
(4) By safety degrees when use following instances of gasmixture: It cannot be used in Mixture of combustible anesthetic gas with air and Mixture of Oxygen with Oxygenation;
(5) By the duty: fitful loading and continuous running (admitted time for loading & unloading----30min/10min);
According to GB7247.1---2001, there are four kinds laser products.
2 type signments
H L M � 1 -30 A
H: Holmium
L: Laser
M: Medical apparatus and instruments
1 : The numbers of Laser
30: The watt that the largest output power will ont be less than
A: Video mood: A stands for digital disply
Treatment range
The range of sections and illness where foreign alike apparatuses were used were fairly wide. The validated scopes for this equipment are:
1 Department of dermatology
It is used to cure granuloma pyogenicum, senile wart, hyperkeratosis senilis, codyloma acuminatum, etc.
2 Department of obstetrics and gynecology
It is used to cure cervical erosion.
3 E.N.T. department
It is used to cure rhinopolypus, papilloma on throat, etc.
4 Urological department
It is used to cure bladder carcinoma (tumour), etc.
Mainly technical didicators
1 Output wavelength of the service laser: 2.1um;
2 Working way of Laser: pulse;
3 Width of pulse: 300us, 600us adjustable;
4 Repeated frequency of pluse: 5-15Hz (adjustable);
5 Single pulse energy: 0.2-2.0J (adjustable);
6 The peak value of optical fiber terminal output: not less than 30W (±20%);
7 Emanative angles of light: 300mrad
8 Unstable degree of power: St≤±20%;
9 Repetition of output power: ±20%
10 Laser mode: multiple mode;
11 Output mode of laser: be transferred by optical fiber;
12 Indicating light: green semiconductor laser, wavelength: 532nm±5nm, intensity≤5Mw
13 Starting time: ≤10 min;
14 Input power: ≤5Kva;
15 Bulk: length �width�height: 850�500�970
16 Weight: 130Kg (including cooling water).
|
|
|
|
| |
|
|
|